Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add filters








Year range
1.
The Korean Journal of Pain ; : 228-237, 2012.
Article in English | WPRIM | ID: wpr-74030

ABSTRACT

BACKGROUND: Milnacipran is a balanced serotonin norepinephrine reuptake inhibitor with minimal side effects and broad safety margin. It acts primarily on the descending inhibitory pain pathway in brain and spinal cord. In many animal studies, intrathecal administration of milnacipran is effective in neuropathic pain management. However, there is no study for the neurological safety of milnacipran when it is administered neuraxially. This study examined the neurotoxicity of epidural milnacipran by observing behavioral and sensory-motor changes with histopathological examinations of spinal cords in rats. METHODS: Sixty rats were divided into 3 groups, with each group receiving epidural administration of either 0.3 ml (3 mg) of milnacipran (group M, n = 20), 0.3 ml of 40% alcohol (group A, n = 20), or 0.3 ml of normal saline (group S, n = 20). RESULTS: There were no abnormal changes in the behavioral, sensory-motor, or histopathological findings in all rats of groups M and S over a 3-week observation period, whereas all rats in group A had abnormal changes. CONCLUSIONS: Based on these findings, the direct epidural administration of milnacipran in rats did not present any evidence of neurotoxicity in behavioral, sensory-motor and histopathological evaluations.


Subject(s)
Animals , Rats , Brain , Cyclopropanes , Injections, Epidural , Neuralgia , Norepinephrine , Serotonin , Spinal Cord
2.
The Journal of Korean Academy of Prosthodontics ; : 194-201, 2010.
Article in Korean | WPRIM | ID: wpr-158525

ABSTRACT

PURPOSE: The purpose was to compare the marginal fidelity and the fracture resistance of the zirconia crowns according to the various coping designs with different thicknesses and cement types. Material and METHODS: Zirconia copings were designed and fabricated with various thicknesses using the CAD/CAM system (Everest, KaVo Dental GmbH, Biberach., Germany). Eighty zirconia copings were divided into 4 groups (Group I: even 0.3 mm thickness, Group II: 0.3 mm thickness on the buccal surface and the buccal half of occlusal surface and the 0.6 mm thickness on the lingual surface and the lingual half of occlusal surface, Group III: even 0.6 mm thickness, Group IV: 0.6 mm thickness on the buccal surface and the buccal half of occlusal surface and the 1.0 mm thickness on the lingual surface and the lingual half of occlusal surface) of 20. By using a putty index, zirconia crowns with the same size and contour were fabricated. Each group was divided into two subgroups by type of cement: Cavitec(R) (Kerr Co, USA) and Panavia-F(R) (Kuraray Medical Inc, Japan). After the cementation of the crowns with a static load compressor, the marginal fidelity of the zirconia crowns were measured at margins on the buccal, lingual, mesial and distal surfaces, using a microscope of microhardness tester (Matsuzawa, MXT-70, Japan, x100). The fracture resistance of each crown was measured using a universal testing machine (Z020, Zwick, Germany) at a crosshead speed of 1 mm/min. The results were analyzed statistically by the two-way ANOVA and oneway ANOVA and Duncan's multiple range test at alpha= .05. RESULTS: Group I and III showed the smallest marginal fidelity, while group II demonstrated the largest value in Cavitec(R) subgroup (P .05). Panavia-F(R) subgroup showed significantly higher fracture resistance than Cavitec(R) subgroup in group I and II (P < .05). CONCLUSION: Within the limitation of this study, considering fracture resistance or marginal fidelity and esthetics, a functional ceramic substructure design of the coping with slim visible surface can be used for esthetic purposes, or a thick invisible surface to support the veneering ceramic can be used depending on the priority.


Subject(s)
Cementation , Ceramics , Collodion , Crowns , Esthetics , Japan , Zirconium
3.
The Journal of Korean Academy of Prosthodontics ; : 406-415, 2009.
Article in Korean | WPRIM | ID: wpr-153198

ABSTRACT

PURPOSE: The purpose of this study was to compare the marginal fitness and fracture load of the zirconia copings according to the design with different thickness and coloration. MATERIAL AND METHODS: The evaluation was based on 80 zirconia copings. Zirconia copings were fabricated in design with different thicknesses using CAD/CAM system (Everset, KAVO dental GmbH, Biberach, Germany). The designs of copings were divided into four groups. The first group consisted of copings with uniform thickness of 0.3 mm. The thickness in the second group was 0.3 mm on the buccal surface and 0.6 mm on the lingual surface. The third group consisted of coping with uniform thickness of 0.6 mm. The thickness in the fourth group was 0.6 mm on the buccal surface and 1mm on the lingual surface. Each group consisted of 10 colored and 10 uncolored copings. Half of the copings (40) processed with a milling system according to the specific design were sent to be given a color (A3) through saturation in special dye by a manufacturing company. Just after sintering, the marginal discrepancies of copings were measured on the buccal, lingual, mesial and distal surfaces of metal die, under a Video Microscope System (sv-35, Sometech, Seoul, Korea) at a magnification of x100. It was remeasured after the adjusting of the inner surface. Next, all copings were luted to the metal dies using reinforced cement {GC FujiCEM (GC Corp. Tokyo, Japan)} and mounted on the testing jig in a Universal Testing Machine (Instron 4467, Norwood, MA, USA). The results were analyzed statistically using the one-way ANOVA test. RESULTS: The obtained results were as follow: 1. The measured value of marginal discrepancy right after sintering was the greatest in the contraction of the buccal area in all groups, except for group I2. 2. There was no significant difference of marginal fitness among the groups in the colored zirconia group (P.05), with no significance. CONCLUSION: There was difference in the marginal fitness according to the design and coloration of zirconia copings right after sintering, but it was decided that the copings may well be used clinically if the inner surface are adjusted. The copings should be thick enough for the reinforcement of fracture strength. But considering the esthetics of the visible surfaces (labial and buccal surface), the thickness of copings may be a little thin, without giving any significant effect on the fracture strength. This type of design may be considered when giving priority to preservation of tooth or esthetics.


Subject(s)
Ceramics , Collodion , Contracts , Esthetics , Glass Ionomer Cements , Reinforcement, Psychology , Tokyo , Tooth , Zirconium
4.
The Journal of the Korean Academy of Periodontology ; : 209-221, 2007.
Article in Korean | WPRIM | ID: wpr-8000

ABSTRACT

Recently, immediately after losing teeth, implant placement has been greatly attempted. Implant can help restoration of tooth functions within short time. This study was an attempt to examine the extent of osseointergation when the implants will be placed immediately after teeth extraction using domestic implant systems. Implants were inserted in beagle dogs and evaluated the clinical, radiological, histological and histomorphometric assay at 6 weeks and 12 weeks. For experimental materials, STAGE-1(R)(4.1x8mm, Lifecore, USA), SS-III(R)(4.0x8mm, OSSTEM, Korea) and IFI(R)(4.0x8 mm, DIO, Korea) implants treated with RBM were placed. All the placed site showed normal results without fail and inflammation clinically and radiologically. As a result of measurement by periotest, it showed -2 ~ -5 and stable status comprehensively. There was no statistically significant difference among implants(p<0.05). Bone tissue adjacent to implant showed increased marrow tissue at 6 weeks. Nevertheless, osteogenic structure was not observed remarkably. In a 12 weeks opinion, bone tissue composed of osseointegration along implant interface showed significantly decreased marrow tissue containing central vessels unlike a 6 weeks opinion and matured compact bone whose osteogenic structure is well formed. BIC were 42.4%, 32.0% and 34.9%, respectively in 6 weeks and there was no statistically significant difference among groups(p<0.05). In 12 weeks, BIC were 58.8%, 61.9% and 57.5%, respectively and there was no statistically significant difference among groups(p<0.05). It is considered that all 3 implant systems are suitable for immediate implant placement.


Subject(s)
Animals , Dogs , Bone and Bones , Bone Marrow , Inflammation , Osseointegration , Tooth
5.
The Journal of the Korean Academy of Periodontology ; : 223-236, 2007.
Article in Korean | WPRIM | ID: wpr-7999

ABSTRACT

This study was attempted to evaluate home-manufactured implants by placing Stage-1(R) Implant (Lifecore. Co., USA) whose surface is treated with RBM that has already been varified clinically, Chaorum(R) Implant(Chaorum Co., Korea) whose surface treatment is same as that of Stage-1 Implant and Atlas(R) Implant(Cewellmedi Co., Korea) whose surface is treated with anodic oxidation immediately after the teeth of experimental animals were extracted to compare histological findings among them. Stage-1 Implant(diameter: 3.5mm, length: 10mm), Chaorum Implant(diameter: 3.3mm, length: 8.5mm) and Cowell medi Implant(diameter: 4.0mm, length: 8.0mm) were placed into the mandible premolars of 2 adult beagle dogs immediately after their teeth were extracted, and then histological findings were analyzed at 6 weeks. After those implants were inserted directly after their teeth were extracted, the results of periotest were recorded, radiography was done, the subjects went through thorough control for 6 weeks, and then comparison among periotest, radiography and histological finding was made. After comparison of those findings, the values of periotest were satisfactory and bone healing was relatively satisfactory on radiography at 6 weeks. For osseointegration with the bone tissue, Stage-1 was 45.3%, Chaorum 55.3%, and Cowellmedi 52.5%, which was a satisfactory result. Although implant surgery immediately after teeth were extracted involves difficulties among recent implant surgeries, it is being frequently used in that it may reduce surgery hours, the frequency of surgery, and bone loss for patients. This experiment was conducted to evaluate the technological levels of home-manufactured implants that have been remarkably developed in recent years and in conclusion, those implants showed nearly similar result.


Subject(s)
Adult , Animals , Dogs , Humans , Bicuspid , Bone and Bones , Mandible , Osseointegration , Radiography , Tooth
6.
Journal of the Korean Association of Oral and Maxillofacial Surgeons ; : 380-383, 2006.
Article in Korean | WPRIM | ID: wpr-25664

ABSTRACT

Tetanus is rare in Korea due to the introduction of vaccination programs and the advancement in public health. Its common signs are trismus, voice disturbance, neck stiffness, and difficulty in swallowing, etc. A 56 years old man was injured by grasping a high voltage electric cable. After the accident, he fell down on a steel plate and had a head trauma. When he visited Emergency Department, there was multiple electric burn wound on left arm and left facial area. He was hospitalized on a department of neurosurgery, because intra cranial hemorrhage was presumed. 12 days later, he was referred to department of OMFS with developed painful masseter spasms and trismus. That night he violently bit his tongue with his denture. Because masseter muscle and temporal muscle constriction was involuntary, tongue was lacerated and denture was distorted. At first we supposed that the symptom was related with neurologic disturbance following head trauma or electric shock. But it was revealed that trismus was caused by tetanus on an electrophysiological test. By using mechanical ventilation and administration of tetanus immunoglobulin, muscle-relaxant, and sedatives at ICU, symptoms had subsided (4-weeks). Because tetanus is rare disease, we rarely suppose tetanus infection to be a cause of a trismus. Especially it is more difficult to diagnose in patient who has head trauma, burn and neurologic problem as in this case.


Subject(s)
Humans , Middle Aged , Arm , Burns , Burns, Electric , Constriction , Craniocerebral Trauma , Deglutition , Dentures , Emergency Service, Hospital , Hand Strength , Hemorrhage , Hypnotics and Sedatives , Immunoglobulins , Korea , Masseter Muscle , Neck , Neurosurgery , Public Health , Rare Diseases , Respiration, Artificial , Shock , Steel , Temporal Muscle , Tetanus , Tongue , Trismus , Vaccination , Voice Disorders , Wounds and Injuries
SELECTION OF CITATIONS
SEARCH DETAIL